Ce ISO Marked Hv-600A Medical Breathing Apparatus Ventilator with Low Price
- Model NO.: HV-600A
- Kind: Surgical Equipment
- Group: All People
- Medical Device Regulatory Type: Type 3
- Certificate: Ce ISO
- Gas Requirement: Medical Oxygen and Nitrous Oxide
- Mode: Pneumatic Power and Electric Control System
- Modes of Ventilation: A/C, Ippv, Sippv, Imv, Simv, Peet. Manual etc
- Maximum Minute Ventilation: More Than 18L/ Min
- Trademark: healicom
- Specification: CE ISO
- HS Code: 9019200000
- Type: Ventilator
- Certification: CE, ISO13485
- LCD Display: With LCD Display
- Medical Devices Reg./Record No.: Gsyjxz20143540786
- Display: 10.4′′ LCD Display
- Safety Valve: <12.5 Kpa
- Power Requirement: 100-120 VAC, 50/60 Hz
- Warranty: 12 Months
- Ilator Compliance: Less Than 30 Ml/Kpa
- Transport Package: Carton
- Origin: Jiangsu, China
The HV-600A ventilator is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc. it provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation.
Â
The automatic conversion for standby power while AC power outage, keep working not less than 1 hour.
Â
Component Details
Display: 10.4''LCD Display Following Parameters & Real time waveform display
(1) Gas drive and electrical control, time-pressure switching and pressure limit control.
(2) A high-brightness digital display is used to present the control frequency, tidal volume, throughput, overall respiratory rate, spontaneous breathing frequency, etc.
(3) A highly sensitive and responsive pressure sensor and a flow sensor are used to measure, control and display the airway pressure and gas flow rate and the ventilator is equipped with automatic throughput compensation.
(4) In case of an abnormality to the ventilator or misoperation, the ventilator can raise a visual-audible alarm to automatically protect itself.
Â
Ventilator Construction:
-Environmental Protection Material construction, hardly to be broken.
-Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Â
TECHNIQUES SPECIFICATIONS | |
Physical specifications | |
Display |
10.4'' LCD Display |
Mode |
pneumatically powered and electrically controlled system |
Trolley |
Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Technical Specifications | |
Gas requirement |
Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa |
safety valve |
<12.5Â kPa |
Respiratory Rate |
1 ~ 99 bpm |
Maximum Minute ventilation |
≥18L / min |
modes of ventilation |
A/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUAL |
Ventilator compliance |
≤30 Ml/kPa |
PEEP |
0 ~ 1.0 kPa |
Ptr |
-1.0kPa~1.0kPa |
IMV frequency |
1~20 bpm |
I/E Ratio |
4:1~1:4, Has the inverse ratio ventilation |
Tidal Volume range |
0~2000ml |
Inspiratory Plateau |
0~1s |
Maximum Safety Pressure |
≤ 6.0kPa |
Sigh |
one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
Pressure limit range |
1.0~ 6.0kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating |
Lower: 0.1 kPa ~ 6.0 kPa;Â Â Upper: 0 ~ 5.0Â kPa |
±0.2 kPa | |
Ventilation Volume alarm |
≥ 18L/ MIN |
Power Supply Alarm |
Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
Operating conditions | |
Ambient temperature |
10Â ~Â 40oC |
Relative humidity: |
no higher than 80 % |
Atmospheric pressure |
860 hPa ~ 1060 hPa |
Power requirement |
100-120 Vac, 50/60 Hz;Â |
Attention: the AC power supply used for the ventilator machine must be well  grounded. | |
Attention: the ventilator machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. | |
Storage | |
Ambient temperature |
-15oCÂ ~Â +50oC |
Relative humidity |
no higher than 95 % |
Atmospheric pressure |
86 kPa ~ 106 kPa. |
It should be stored in a room without corrosive gas and well ventilated | |
Package | |
packaging box |
comply with the requirement of GB/T 15464 |
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation | |
Moisture protection and rain protection to ensure that product is protected from natural damage. | |
Safty & Alarm | |
Gas source pressure |
Immediate alarm; "high level alarm" indicator flickers raising an audible alarm. |
Airway Pressure Alarm |
The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm. |
Tidal Volume Alarm |
Lower than 50ml, The alarm will be raised after one breathing cycle. |
Ventilation Volume Alarm |
Lower: 0~12L/Min;Â Â Up: 18L/ Min |
Battery Voltage Alarm |
It alrms when the battery voltage is lower than 10.5V. |
Power On Self Test |
Self test before working, assure it's working normally. |
STANDARD CONFIGURATIONS | |
QTY |
NAME |
1 set |
Main unit |
4 pcs |
Adult threaded pipe (Silica) |
1 set |
Child threaded pipe (single use) |
1 pc |
Oxygen Tube |
1pc |
Y-Pipe |
2pcs |
Mask (Silicom) |
2pcs |
Leather Bag |
2pcs |
Fuse |
1pc |
Power Line |
1pc |
Oxygen pressure reducer |
4 pcs |
Hoop |
1pc |
Battery |
1pc |
Tools Attachment |
1 set |
humidifier |
1 set |
English Version User Manual |
Standardized Herbal Extract
A standardized herbal extract is an herb extract that has one or more components present in a specific, guaranteed amount, usually expressed as a percentage. The intention behind the standardization of herbs is to guarantee that the consumer is getting a product in which the chemistry is consistent from batch to batch. This practice has developed out of the drug model of herbal medicine, in which modern scientists have attempted to identify the components of a plant that have definite pharmacological activity in the body. Unfortunately, while scientists can isolate many constituents from an herb and discover how particular chemicals may act in the body, they inadvertently remove or overlook components that may contribute to the activity of the whole herb. Consequently, standardization may concentrate one constituent at the expense of other potentially important ones, while changing the natural balance of the herb`s components.
Standardized Herbal Extract
Standardized Herbal Extract,Green Tea Extract,Black Currant Extract,Cranberry Extract, Green Coffee Bean Extract
Excellent Health Products Co.,Ltd , http://www.sino-excellent.com